Maanshan Ruika Metal Products Technology Co., Ltd.

Top supplier for air source heat pumps,leader OEM/ODM heat pums service Hot water and heating/cooling solution! Welcome to contact kelly@lnashp.com

Manufacturer from China
Active Member
5 Years
Home / Products / Heating And Cooling Heat Pump /

65KW CO2 Heating And Cooling Heat Pump 380V CO2 Heat Pump 4.7 COP

Contact Now
Maanshan Ruika Metal Products Technology Co., Ltd.
Province/State:anhui
Country/Region:china
Contact Person:MsKelly
Contact Now

65KW CO2 Heating And Cooling Heat Pump 380V CO2 Heat Pump 4.7 COP

Ask Latest Price
Video Channel
Brand Name :LN
Model Number :DKFXRS-19II/CY
Certification :CE ISO CCC
Place of Origin :China
MOQ :Negotiable
Price :Negotiable
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :80000pcs/year
Delivery Time :1-30 working days
Packaging Details :standard export package, or as per customer request
Specificaition :DKFXRS-19II/CY/ air source heat pump water heater
Power :220/380V as per customer choice
Condenser :High efficiency shell and tube heat exchanger
Function :Cooling,Heating,hot water,heating/hot water,DHW
Refrigerant :R744 CO2
Installation :Freestanding,Wall Mounted,Wall Mounted/Freestanding
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Features of 20-65 kw CO2 Air To Water Heat Pump

The carbon dioxide heat pump includes a shell. A partition is arranged horizontally in the shell, and a heat exchanger assembly is fixed above the partition. The heat exchanger assembly includes heat exchangers arranged obliquely on both sides of the partition, and is arranged above the heat exchanger assembly. There are fans. In the present invention, a horizontal baffle is arranged inside the shell, the baffle divides the shell into upper and lower spaces, the heat exchanger assembly is installed above the baffle, and the piping system and the circulation system are installed in the space below the baffle. , Separate the heat exchanger assembly and the piping system by the baffle to avoid the convection between the heat exchanger and the piping system, so as to prevent the mutual influence between the two, which is beneficial to the normal operation of the carbon dioxide heat pump.

Product Details of 20-65 kw CO2 Air To Water Heat Pump

  • Unique water printing label optional.
  • R32 CO2 free refrigerant optional.
  • Only 1 to 5 deg C small water temperature difference to ensure more stable water temperature
  • Reliable Japanese brand compressor.
  • Worldwide different color cabinets for customized design.
  • Insufficient water flow protection & high/low pressure protection.
  • Wide capacity range models for distributor.
  • Rust free Spiral Titanium PVC condenser to ensure high efficiency and long lifespan.


Application:It is suitable for heating and hot water supply of family, villa, apartment,business restaurant, hotel and multi-floor living building in city and village.

Company introduction:

Leomon technology rnjoy rich experience in supplying air source heat pumps, supply its own brand and OEM for customers worldwide.

Products series: air source heat pumps for household, water heater, swimming pool heat pumps, heating system

Keep working at technical and commercial ability, company is athorized over 300 patents, norminated factory for supplying heat pumps.

Quality Control: DC Inverter CO2(R744) Air Source Heat Pump Hot Water And Heating System

100% products inspection before delivery, 3 phrases test to guarantee right quality and quantity before delivery

Whole lifespan after sale service

Some specification of 20-65 kw CO2 Air To Water Heat Pump

Name Carbon Dioxide heat pump unit
Model number SFYRS-60II
Power supply 380V/50Hz
Heating mode One-time formula
Performance parameter Test Standard Standard working condition Low temperature condition High temperature condition
Heat capacity (kW) 64.4 55.4 53.8
Electricity Consumption (kW) 13.7 13 16.3
COP 4.7 4.3 3.3
Hot Water flow (m³/h) 1.38 1.03 0.61
Maximum current 34A
Weight 1000kg
Contour dimension Length1500*Wide1200*High1800
Design pressure High pressure side:14.5MPa,Low pressure side6MPa
Compressor Semi-closed reciprocating
Refrigerant name R744 ( CO2 )
Water heat exchanger Copper bushing changer
Heat source side exchanger Plate heat exchanger
Feed pump 0.75kW
Operation Panel Color touch screen
Control System Siemens
Water connection Feed water inlet DN40Internal thread
Hot Water Inlet DN20Internal thread
Insulated water inlet DN20Internal thread
Heat connection Hot Water Inlet DN40Internal thread
Heat source water outlet DN32Internal thread
SCOPE of use Feed water temperature 5~29℃
Effluent temperature 55~90°℃
Maximum flow 2.5m³/h
Ambient temperature ’-10~43℃
Notes Standard working condition Inlet temperature: 15 °C, outlet temperature: 55 °C, heat source water inlet temperature: 15 °C
Low temperature condition The inlet temperature is 9 °C, outlet temperature is 55 °C, and the inlet temperature of heat source water is 10 °C
High temperature condition The inlet temperature is 15 °C, the outlet temperature is 90 °C, and the inlet temperature of heat source water is 15 °C