Add to Cart
Features of 2kW-9kW Hot Water Heaters Services Air source heat pumps HVAC system:
*Economical and high-efficiency: Save average 70% heating cost than electric heaters.
*Water Circulation: Easy installation and acquaintance
*Quiet Running: High-efficiency, low noise rotary compressor, low noise fan, the main unit works at extremely quiet condition.
*Intelligent: Full automatic and intelligent controller, no need any manual operation.
Longer life span 2kW-9kW Hot Water Heaters Services Air source heat pumps HVAC system
Shell, air energy heat pump, shock absorber, radiator, copper pipe and supporting feet; the air energy heat pump is arranged inside the shell, and both sides of the air energy heat pump are provided with shock absorbers, and the shock absorbers are embedded in the inner wall of the shell , Where: the shock absorber includes a pressure plate, a connecting rod, a connecting box and a spring; the connecting box is inlaid on the inner wall of the shell; the pressure plate is welded to one end of the connecting rod, and the spring is welded to the other end of the connecting rod and inserted into the connection The inside of the box; the air energy heat pump is clamped and fixed to the inside of the shell based on the pressure plates arranged on both sides; one side of the copper pipe is connected to the water outlet of the air energy heat pump, and the other end of the copper pipe is connected to the external water pipe; The radiator is arranged on the top of the shell, and the radiator is connected with the air energy heat pump based on wires; the supporting feet are arranged on the bottom of the shell. This design provides a relatively stable working environment for the work of the air energy heat pump and prolongs the life of the air energy heat pump.
Company brief introduction
Over 20 years production experience, thanks to R&D hard and smart working, company is authorized over 400 patents, products quality play a lead role in HVAC system field
Over 20% sales volume are invested on improving products research and company service imporovement, we are happy to say"We cannot promise that equipment won't break, that software won't fail, or that we will always be perfect. What we can promise is that if something goes wrong, we will rise to the occasion, take action, and help resolve the issue, and the most important is we have abilidty to solve! ."
Quality control:
100% inspection for each product, 3 phrases test before delivery, free spares supply, good prize if found any unqualified items
Production line:
3 production lines to guarantee production capacity and quick delivery, 2 shifts working
Technical paremeters of 2kW-9kW Hot Water Heaters Services Air source heat pumps HVAC system
Item | KCHR-8I/BP Side wind | |
Rated voltage | 220V~50Hz | |
Cooling and heating | Nominal cooling capacity | 7.8kW(2kW-9kW) |
Nominal cooling power consumption | 2.77KW | |
Nominal cooling(COP) | 2.81 | |
IPLV | 4.11 | |
Nominal heating capacity | 8.4kW(2.5kW-9.6kW) | |
Nominal heating power consumption | 2.78KW | |
Heating | Nominal heating capacity | 6.8KW |
Nominal heating power consumption | 1.75KW | |
Nominal heating(COP) | 3.88 | |
Maximum operating current | 20A | |
Maximum power consumption | 4KW | |
Rated water flow | 1.34m²/h | |
Refrigerant/charge volume | R410A/1750g | |
noise | ≤54dB(A) | |
Water resistance | ≤14kPa | |
Maximum working pressure on low pressure/high pressure side | 4.5Mpa/0.15Mpa | |
Allowable working pressure on suction/exhaust side | 4.5Mpa/0.15Mpa | |
Anti-shock level | I | |
waterproof level | IPX4 | |
Unit size (l× w × h) | 1030×410×865(mm) | |
(Cold and warm) Caliber of inlet and outlet | DN25 | |
(Hot water) Caliber | DN20 | |
Application area | 60㎡ |