Maanshan Ruika Metal Products Technology Co., Ltd.

Top supplier for air source heat pumps,leader OEM/ODM heat pums service Hot water and heating/cooling solution! Welcome to contact kelly@lnashp.com

Manufacturer from China
Site Member
5 Years
Home / Products / DHW Heat Pump /

Hotel Air Source Heat Pump Domestic Hot Water DN32 DHW Heat Pump 50HZ

Contact Now
Maanshan Ruika Metal Products Technology Co., Ltd.
Province/State:anhui
Country/Region:china
Contact Person:MsKelly
Contact Now

Hotel Air Source Heat Pump Domestic Hot Water DN32 DHW Heat Pump 50HZ

Ask Latest Price
Video Channel
Brand Name :LN
Model Number :DKFXRS-9I/CY
Certification :CE ISO CCC
Place of Origin :China
MOQ :Negotiable
Price :Negotiable
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram-25C cold winter monoblock air source new energy heat pump inverter heatpump air to water
Supply Ability :80000pcs/year
Delivery Time :1-30 working days
Packaging Details :standard export package, or as per customer request
Heat Source Type :Air Source Heat Pump
Application :Appartment, House, Villa, School, Factory, hotel
Cooling Method :Water chiller
Work Environment :Low-temperature Heat Pump
Working ambient :-30-50℃
Type :Central Air Conditioners Radient floor heating
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Features of Low Ambient Temperature Operation Air Source Heat Pump for Hotel

Low Ambient Temperature Operation Air Source Heat Pump for Hotel , Including evaporator, compressor, condenser, electronic expansion valve and economizer. The two ends of the housing of the economizer are respectively connected with the condenser and the electronic expansion valve, and the two ends of the heat exchange coil in the economizer are respectively connected with the evaporator and the compressor, so that the low-temperature and low-pressure gas in the evaporator is evaporated The refrigerant exchanges heat with the high-temperature and high-pressure liquid refrigerant before throttling in the economizer and then enters the compressor to increase the superheat of the return air of the compressor. It can also increase the subcooling degree before the refrigerant throttling. In the case of high energy consumption, the higher energy efficiency utilizes the high-temperature and high-pressure liquid refrigerant before throttling and the low-temperature and low-pressure gaseous refrigerant before the return gas to exchange heat to achieve the purpose of increasing the return gas superheat. It overcomes the disadvantages of the prior art that the cost increase and the volume of the main machine are increased by enlarging the evaporator, and the cost of the evaporator is reduced under the effect of ensuring the superheat of the return air of the compressor, and the volume of the main machine is reduced.

Energy-saving low-temperature compensation air energy water heater, air energy water heater includes air energy heat pump, heat preservation water tank and solar battery pack; heat preservation water tank is respectively connected with air heat pump and solar battery pack; the heat preservation water tank is provided with a control switch outside, and the heat preservation water tank has a built-in spring The heating wire is connected to the control switch based on the wire; the solar battery pack includes a photovoltaic panel, a controller, and a power storage unit, and the photovoltaic panel, the controller, and the power storage unit are connected in sequence, and the power storage unit is connected to the control switch connection. The utility model uses the solar battery pack to provide power for the heating wire. When the temperature of the hot water in the heat preservation water tank is lower than a certain temperature, the heating wire starts to work and generates heat to provide low temperature compensation for the hot water in the heat preservation water tank; and an electric heating wire is added The contact area with the water in the heat preservation water tank increases the contact area between the heating wire and the water; it ensures stable hot water use and saves electricity consumed during low temperature compensation.

Some specifications of Low Ambient Temperature Operation Air Source Heat Pump for Hotel

Spec. DKFXRS-9I/CY DKFXRS-11I/CY DKFXRS-11II/CY DKFXRS-16I/CY DKFXRS-16II/CY DKFXRS-19II/CY DKFXRS-38II/CY
Nominal heating at room temperature(kW) 9.6 10.9 10.8 16 16.4 17.4 38.9
Nominal power consumption at room temperature(kW 2.17 2.63 2.7 3.9 4.1 4.6 8.82
Low temperature heating(kW) 4.1 4.65 4.8 7.8 7.5 8.5 17.6
Low temperature power consumption(kW) 1.85 2.1 2.16 3.37 3.4 3.68 7.3
Maximum input power(kW) 3 4.2 4.2 6.6 6.8 8.5 17
Maximum current(A) 16 23 8A 32 12 15 30
Power Spec.(Hz) 220V-50 220V-50 380V3N-50 220V-50 380V 3N-50 380V3N-50 380V 3N-50
Refrigerant/charge amount R22/2500g R22/5600g R22/5600g R22/6000g R22/6000g R22/6500g R22/6500gx2
noisedb(A) <55 <62 <62 <65 <65 <66 <68
Water resistancekPa <55 <55 <55 <100 £100 <65 <65
Anti-shock level I I I I I I I
waterproof level IPX4 IPX4 IPX4 IPX4 IPX4 IPX4 IPX4
Circulation port diameter DN20 DN32 DN32 DN32 DN32 DN32 DN40
Unit size (mm) 1010x350x835 1030x410x1390 1030x410x1390 1030x410x1390 1030x410x1390 780x820x1700 1550x780x1700
Unit Weight(kg) 87 142 142 148 149 265 435

Some projects of Low Ambient Temperature Operation Air Source Heat Pump for Hotel

About the detailed information of service, you can contact with our sales personnel!

Hotel Air Source Heat Pump Domestic Hot Water DN32 DHW Heat Pump 50HZHotel Air Source Heat Pump Domestic Hot Water DN32 DHW Heat Pump 50HZ

Inquiry Cart 0